RADIATION DOSE MEASUREMENT OF PATIENT’S FAMILLY THYROID ORGAN ON HEAD CT SCAN EXAMINATION OF PEDIATRIC

Authors

  • Ayu Wita Sari STIKes Guna Bangsa Yogyakarta
  • Maizza Nadia Putri STIKES Guna Bangsa Yogyakarta
  • Fajril Musrifah STIKES Guna Bangsa Yogyakarta

DOI:

https://doi.org/10.54973/miror.v2i2.254

Keywords:

Dosis Radiasi, Organ Tyroid, Ct Scan, Pediatrik

Abstract

Pediatric Ct Scan is a quick and painless examination that uses x-ray equipment to create detailed images of the child’s internal organs, bones, soft tissues and blood vessels. Pediatric Ct Scan examinations are used to help diagnose abdominal pain and evaluate trauma injuries. This type of research is quantitave research using analytical observational methods, this research has been done on 25 April- 16 June 2022 with 10 patient’s famillies as research sample. Measurement of the radiation dose of the tyroid organ of the patien.s famillis using a DMC 300 pendose measuring instrument by means of a tool tied to the left side of the patient’s famillies neck (the part that is not covered by the apron). The results of the study of the radiation dose of the tyroid organs of the patient’s family produced avarage for a scanogram of 0,001 mSb, for scanning results an average of 0,0187 mSv was obtained, the average value of the quivalent dose was 0,0187 mSv and the average value of the effective dose was 0,0000748 mSv. The average obtained is still categorized as safe for the general public when compared to PERKA BAPETEN no.8 of 2011.

Downloads

Download data is not yet available.

References

Ade Heryana. (2019). Metodologi Penelitian Kesehatan Masyarakat. Deepublish, 176–177.

Alatas, Z. (2017). Risiko Radiasi Dari Computed Tomography Pada Anak. Jurnal Forum Nuklir, 8(2), 181.

Ayu Novita Sari, Natalia Silalahi, & Guidio Leonarde Ginting. (2015). Sistem Pakar Diagnosa Penyakit Kelenjar Tiroid. Jurnal Riset Komputer (Jurikom), 3(2), 18–20.

Bapeten. (2011). Jdih.Bapeten.Go.Id. Peratutan Badan Pengawas Nuklir Ri No 8tahun 2011.

Bapeten. (2013). Badan Pengawas Tenaga Nuklir. Nuklir, Peraturan Kepala Badan Pengawas Tenaga Nuklir Nomor 4 Tahun 2013 Tentang Proteksi Dan Keselamatan Radiasi Dalam Pemanfaatan Tenaga.

Bapeten. (2014). Badan Tenaga Nuklir Nasional. In Batan (Ed.), Proteksi Dan Keselamatan Kerja Radiasi Batan.

Bapeten. (2020). Jdih.Bapeten.Go.Id. Peratutan Badan Pengawas Nuklir Ri No 4 Tahun 2020.

Bapeten. (2021). Penetapan Nilai Tingkat Panduan Diagnostik Indonesia (Indonesia Diagnostik Refence Level) Untuk Modalitas Sinar-X Ct Scan Dan Radiografi Umum.

Rizki, M. R., & Nawangwulan, S. (2018). Metodologi Penelitian Kesehatan. 66. Sahara, Astuti.

Sari, A. W., & Sam, S. Y. (2021). Effect of mAs on the Radiation Doses Received by Eyes Organ at Cranium Examination. In Proceedings of the 1st International Conference on Electronics, Biomedical Engineering, and Health Informatics (pp. 541-547). Springer, Singapore.

Utari Sejati1), N. (2021). Literatur Revieuw: Analisa Teknik Pemeriksaan Ct-Scan Thorax Pada Kasus Terkonfirmasi Positif Covid-19. Webinar Nasional Pakar Ke 4 Tahun 2021, Indonesia, 1(1), 1–6.

W.Long, B., Rolins, J. H., & J.Smith, B. (2015). Merrlli’s Atlas Of Radiographic Positioning And Procedures. Elsevier.

Yunus, B., Bandu, K., Radiologi, B., Program, M., Kedokteran, S., Kedokteran, F., & Unuversitas, G. (2019). Efek Radiasi Sinar-X Pada Anak-Anak. Makassar Dental Journal, 8(2), 97–104.

Published

12/01/2022

How to Cite

Sari, A. W., Putri, M. N., & Musrifah, F. (2022). RADIATION DOSE MEASUREMENT OF PATIENT’S FAMILLY THYROID ORGAN ON HEAD CT SCAN EXAMINATION OF PEDIATRIC. Medical Imaging and Radiation Protection Research (MIROR) Journal, 2(2), 41–46. https://doi.org/10.54973/miror.v2i2.254