TEKNIK PEMERIKSAAN COMPUTED TOMOGRAPHY SCANNING (CT-SCAN) THORAKS DENGAN KLINIS LIMFOMA DI INSTALASI RADIOLOGI RSUD ARIFIN ACHMAD

Penulis

  • Luthfi Farhan Yusuf Universitas Awal Bros

DOI:

https://doi.org/10.54973/miror.v4i1.960

Kata Kunci:

CT Scan; , Thorax; , Lymphomas; , radiologi

Abstrak

At the Radiology installation of RSUD Arifin Achmad, a thoracic CT-scan examination with  clinical indications of lymphoma reveals differences in the procedure compared to field practices. The  theoretical approach involves a slice thickness of 5-10 mm and a contrast injection delay of 2 seconds.  However, in the practice, a slice thickness of 10 mm is used, and the contrast injection has either a 0- second delay or no delay.

The research conducted is qualitative with a case study approach, focusing on three  radiographers at RSUD Arifin Achmad in Riau Province. Data collection methods include observation,  interviews, and documentation. The gathered data is then analyzed to draw conclusions based on the  obtained information.

The research findings indicate that in the Radiology Installation of RSUD Arifin Achmad, the  thoracic CT-scan technique for lymphoma cases involves a slice thickness of 10 mm and a contrast  injection with either a 0-second delay or no delay. This choice is justified by the fact that manually  injecting the contrast media alone produces results that effectively highlight any abnormalities.

Unduhan

Data unduhan belum tersedia.

Referensi

Bontrager, K. L. (2010). Textbook of positioning and related anatomy (6th ed.). Mosby.

Nesseth, R. (2000). Procedure and documentation for CT and MRI. McGraw-Hill Medical Publishing.

Seeram, E., & Seeram, D. (2008). Image postprocessing in digital radiology: A primer for technologists. Journal of Medical Imaging and Radiation Sciences, 39(1), 23–41. https://doi.org/10.1016/j.jmir.2008.01.004

Wibawa, I. K. P. A., & Ekawati, N. P. (2021). Karakteristik pasien limfoma maligna di Rumah Sakit Umum Pusat Sanglah Denpasar Bali tahun 2018. Jurnal Medika Udayana, 10(1), 47–53.

Diterbitkan

2024-06-29

Cara Mengutip

Farhan Yusuf, L. . (2024). TEKNIK PEMERIKSAAN COMPUTED TOMOGRAPHY SCANNING (CT-SCAN) THORAKS DENGAN KLINIS LIMFOMA DI INSTALASI RADIOLOGI RSUD ARIFIN ACHMAD . Medical Imaging and Radiation Protection Research Journal, 4(1), 17–21. https://doi.org/10.54973/miror.v4i1.960